Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the wp-plugin-mojo domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home2/gecfla/public_html/wp-includes/functions.php on line 6114

Warning: Cannot modify header information - headers already sent by (output started at /home2/gecfla/public_html/wp-includes/functions.php:6114) in /home2/gecfla/public_html/wp-includes/rest-api/class-wp-rest-server.php on line 1893

Warning: Cannot modify header information - headers already sent by (output started at /home2/gecfla/public_html/wp-includes/functions.php:6114) in /home2/gecfla/public_html/wp-includes/rest-api/class-wp-rest-server.php on line 1893

Warning: Cannot modify header information - headers already sent by (output started at /home2/gecfla/public_html/wp-includes/functions.php:6114) in /home2/gecfla/public_html/wp-includes/rest-api/class-wp-rest-server.php on line 1893

Warning: Cannot modify header information - headers already sent by (output started at /home2/gecfla/public_html/wp-includes/functions.php:6114) in /home2/gecfla/public_html/wp-includes/rest-api/class-wp-rest-server.php on line 1893

Warning: Cannot modify header information - headers already sent by (output started at /home2/gecfla/public_html/wp-includes/functions.php:6114) in /home2/gecfla/public_html/wp-includes/rest-api/class-wp-rest-server.php on line 1893

Warning: Cannot modify header information - headers already sent by (output started at /home2/gecfla/public_html/wp-includes/functions.php:6114) in /home2/gecfla/public_html/wp-includes/rest-api/class-wp-rest-server.php on line 1893

Warning: Cannot modify header information - headers already sent by (output started at /home2/gecfla/public_html/wp-includes/functions.php:6114) in /home2/gecfla/public_html/wp-includes/rest-api/class-wp-rest-server.php on line 1893

Warning: Cannot modify header information - headers already sent by (output started at /home2/gecfla/public_html/wp-includes/functions.php:6114) in /home2/gecfla/public_html/wp-includes/rest-api/class-wp-rest-server.php on line 1893
{"id":1668,"date":"2021-03-01T19:18:01","date_gmt":"2021-03-01T19:18:01","guid":{"rendered":"https:\/\/www.gecfla.com\/?page_id=1668"},"modified":"2021-03-22T14:49:33","modified_gmt":"2021-03-22T14:49:33","slug":"university-high-school","status":"publish","type":"page","link":"https:\/\/www.gecfla.com\/university-high-school\/","title":{"rendered":"University High School"},"content":{"rendered":"

Educational<\/b><\/span><\/h2><\/div><\/div><\/div><\/div><\/div>

University High School<\/h2>\n

GEC provided geotechnical engineering and construction materials testing services for the University High School Renovations project with Orange County Public Schools. Project plans included additions to 2, two-story buildings, a new chiller building, parking and drive modifications and two stormwater ponds. During construction GEC provided materials testing services including soil density testing, asphalt testing, fireproofing testing, underdrain inspection and grouting inspection of a sinkhole that developed during construction.<\/p>\n<\/div>

<\/span><\/div>
<\/div><\/div>
<\/div><\/div>
<\/div><\/div>
<\/div><\/div><\/div><\/div>
<\/i><\/div><\/div>
<\/div>
\n

GEC CLIENT<\/strong><\/h3>\n

Orange County Public Schools (OCPS)<\/p>\n<\/div><\/div><\/div>

<\/div><\/div>
<\/div><\/div>
<\/i><\/div><\/div>
<\/div>
\n

ULTIMATE CLIENT<\/strong><\/h3>\n

Orange County Public Schools (OCPS)<\/p>\n<\/div><\/div><\/div>

<\/div><\/div>
<\/div><\/div>
<\/i><\/div><\/div>
<\/div>
\n

PROJECT ELEMENTS<\/strong><\/h3>\n

\u2022 Building foundations
\n\u2022 Stormwater ponds
\n\u2022 Pavements
\n\u2022 Sinkhole subsidence remediation
\n\u2022 Soil density testing and proof rolling inspection
\n\u2022 Fireproofing testing
\n\u2022 Concrete and grout strength testing
\n\u2022 Floor flatness testing
\n\u2022 Underdrain inspection<\/p>\n<\/div><\/div><\/div>

<\/div><\/div><\/div><\/div><\/div><\/div><\/p>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"100-width.php","meta":{"footnotes":""},"class_list":["post-1668","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.gecfla.com\/wp-json\/wp\/v2\/pages\/1668","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.gecfla.com\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.gecfla.com\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.gecfla.com\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.gecfla.com\/wp-json\/wp\/v2\/comments?post=1668"}],"version-history":[{"count":2,"href":"https:\/\/www.gecfla.com\/wp-json\/wp\/v2\/pages\/1668\/revisions"}],"predecessor-version":[{"id":1944,"href":"https:\/\/www.gecfla.com\/wp-json\/wp\/v2\/pages\/1668\/revisions\/1944"}],"wp:attachment":[{"href":"https:\/\/www.gecfla.com\/wp-json\/wp\/v2\/media?parent=1668"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}